All Categories
rtc 4 in 1 sf gas comprehensive analyzer capacitive dew point  cf-0

SF6 Analysis Equipment

Home >  Products >  SF6 Gas Analyzers & Detector >  SF6 Analysis Equipment

GSA-C3/MPDC/RTC 4-in-1 SF₆ Gas Comprehensive Analyzer (Capacitive Dew Point + CF₄)

GSA-C3/MPDC/RTC Digital Intelligent 4-in-1 SF₆ Gas Comprehensive Analyzer with Imported Capacitive Dew Point Sensor, NDIR Purity & CF₄ Sensor, Electrochemical Decomposition Products Sensor, Built-in Pump-Back System, for 10kV-500kV SF₆-Insulated Equipment On-Site Condition Assessment and Early Defect Diagnosis.

  • Description
  • Specifications
  • Applications
  • Advantages
  • FAQ
  • Recommended Products

Description

The GSA-C3/MPDC/RTC is a professional, field-optimized high-end 4-in-1 SF₆ gas comprehensive analyzerexclusively designed for comprehensive condition assessment and early defect diagnosis of SF₆-insulated high-voltage equipment. It fully complies with DL/T 506-2018, IEC 60480:2019, GB/T 8905-2012 and DL/T 2509-2022 standards, adopting world-class imported sensors to ensure reliable and accurate test results.
The instrument integrates humidity (dew point) measurement, SF₆ purity measurement, decomposition products measurement (SO₂/H₂S/CO) and CF₄ measurement into one unit. One-time sampling completes all four test items, reducing gas consumption by 75% compared to using four separate instruments. Its innovative built-in pump-back system can pump the tested gas back into the equipment, minimizing SF₆ emissions and environmental pollution. The unique CF₄ detection function can identify early partial discharge defects involving solid insulation materials that cannot be detected by traditional testers. Equipped with a 7-inch high-resolution color touch screen and intuitive graphical interface, it supports real-time display of all parameters and automatic defect diagnosis. With a built-in 7.4V/10Ah large-capacity lithium battery, it can work continuously for more than 8 hours, making it ideal for all-day on-site inspections. Ideal for daily inspection, preventive maintenance, early defect diagnosis and acceptance test of GIS, SF₆ circuit breakers, power transformers, instrument transformers and other SF₆-insulated equipment.

Specifications

Parameter Specification
Humidity (Dew Point) Measurement
Sensor Type Imported polymer capacitive dew point sensor
Measurement Range -80℃ ~ +20℃ (dew point)
Accuracy ±2℃ (-60℃ ~ +20℃), ±3℃ (-80℃ ~ -60℃)
Resolution 0.1℃
Response Time ≤60 seconds (63% step change)
SF₆ Purity Measurement
Sensor Type Germany Smart-GAS NDIR infrared sensor
Measurement Range 0 ~ 100% SF₆
Accuracy ±0.2% FS
Resolution 0.01%
CF₄ Measurement
Sensor Type Germany Smart-GAS NDIR infrared sensor
Measurement Range 0 ~ 1000ppm
Accuracy ±5% of reading ± 2ppm
Resolution 0.1ppm
Decomposition Products Measurement
Sensor Type Switzerland Membrapor electrochemical sensors
SO₂ Range 0 ~ 1000ppm
SO₂ Accuracy ±5% of reading ± 2ppm
H₂S Range 0 ~ 200ppm
H₂S Accuracy ±5% of reading ± 2ppm
CO Range 0 ~ 500ppm
CO Accuracy ±5% of reading ± 5ppm
Resolution 0.1ppm for all
General Parameters
Sampling Method Built-in pump suction
Flow Rate 0.2 ~ 1.0L/min (adjustable)
Gas Consumption ~2L per complete test
Pump-Back System Yes (built-in)
Automatic Correction Temperature and pressure correction to 20℃, 0.1MPa
Defect Diagnosis Yes (built-in expert system with CF₄ analysis)
Display 7-inch high-resolution color touch screen
Data Storage 1000 groups (with time stamp, power-off protection)
Data Export USB interface, PDF/Excel report generation
Language Support Chinese/English bilingual
Power Supply Built-in 7.4V/10Ah lithium battery + AC 220V±10%, 50Hz charger
Battery Life >8 hours continuous operation
Charging Time ~4 hours (full charge)
Protection Functions Over-pressure, Over-current, Low battery, Pump protection, Electromagnetic interference protection
Dimensions 360×260×150mm (L×W×H)
Weight ~4.8kg (including battery)
Operating Temperature -10℃ ~ +50℃
Operating Humidity ≤90%RH (non-condensing)
Altitude ≤2000m
Compliance DL/T 506-2018, IEC 60480:2019, GB/T 8905-2012, DL/T 2509-2022

Applications

Core Test Objects

  • GIS gas insulated switchgear: 10kV-500kV GIS and HGIS equipment
  • SF₆ circuit breakers: Live tank and dead tank SF₆ circuit breakers
  • SF₆ power transformers: SF₆-insulated power transformers
  • SF₆ instrument transformers: SF₆-insulated CTs and VTs
  • SF₆/CF₄ mixed gas equipment: SF₆/CF₄ mixed gas insulated switchgear and circuit breakers
  • SF₆ gas cylinders: New SF₆ gas quality inspection and recovered gas quality verification

Typical Usage Scenarios

  • Power companies: Daily on-site inspection and preventive maintenance of substation SF₆ equipment
  • Defect diagnosis teams: Early detection and location of internal insulation defects
  • GIS manufacturing plants: Factory type tests and outgoing quality control
  • Third-party testing institutions: On-site acceptance and compliance testing
  • Power plants: Generator transformer and auxiliary equipment gas quality inspection
  • Industrial and mining enterprises: SF₆ equipment routine inspection and maintenance

Advantages

Compliance with International Standards

Fully meets DL/T 506-2018, IEC 60480:2019, GB/T 8905-2012 and DL/T 2509-2022 standards → test results are globally recognized

Industry-Leading 4-in-1 Integrated Design

One instrument completes all four tests, one-time sampling → reduces test time by 75%, saves gas consumption by 75%

World-Class Imported Sensors

Polymer capacitive dew point + German Smart-GAS NDIR dual-component + Swiss Membrapor decomposition products sensors → ensures long-term stability and accuracy of all parameters

Unique CF₄ Detection Function

Identifies early partial discharge defects involving solid insulation materials → enables early warning and preventive maintenance to avoid major accidents

Built-in Pump-Back System

Pumps tested gas back into equipment → minimizes SF₆ emissions, protects the environment, saves gas cost

Automatic Comprehensive Defect Diagnosis

Built-in expert system, analyzes all four parameters and gives defect level → reduces operator skill requirements, eliminates subjective judgment errors

Portable & Long Battery Life

4.8kg lightweight design with 8-hour battery life → ideal for all-day on-site inspections and remote locations

Comprehensive Safety Protection

Multiple protection layers + strong anti-interference ability → ensures safe and reliable operation in harsh field environments

FAQ

Q: Why is CF₄ detection important?

A: CF₄ is an important decomposition product of SF₆ gas under partial discharge and overheating conditions. When the fault involves solid insulation materials (epoxy resin, paper insulation), CF₄ will be generated in large quantities. It appears earlier than SO₂ and H₂S in the early stage of equipment defects, enabling early detection of partial discharge defects that cannot be identified by traditional testers.

Q: Can the tested gas be pumped back into the equipment?

A: Yes. The instrument has a built-in pump-back system that can pump the tested gas back into the equipment after testing. This not only minimizes SF₆ emissions and environmental pollution, but also saves gas purchase costs, especially for expensive high-purity SF₆ gas.

Q: Does it support automatic temperature and pressure correction?

A: Yes. The instrument has built-in high-precision temperature and pressure sensors, which can automatically correct the test results to standard conditions (20℃, 0.1MPa), making it easy to compare test results with standard values and historical data.

Get a Free Quote

Our representative will contact you soon.
Email
Mobile/WhatsApp
Name
Company Name
Message
0/1000

Get a Free Quote

Our representative will contact you soon.
Email
Mobile/WhatsApp
Name
Company Name
Message
0/1000