All Categories
mrt 3127 series portable high voltage insulation resistance tester-0

MRT-3127 Series Portable High Voltage Insulation Resistance Tester

MRT-3127A / MRT-3127B Intelligent Digital High Voltage Insulation Resistance Tester, Graded DC Test Voltage, Supporting IR, DAR and PI Diagnostic Test for HV Electrical Equipment Insulation Condition Assessment.

  • Description
  • Specifications
  • Applications
  • Advantages
  • FAQ
  • Recommended Products

Description

MRT-3127 Series consists of two standardized portable models: MRT-3127A (max 5kV DC, maximum measuring range 2TΩ) and MRT-3127B (max 10kV DC, maximum measuring range 5TΩ). It is a cost-effective digital high voltage megohmmeter developed for routine preventive test and insulation condition evaluation of medium & high voltage electrical equipment in power substations, power plants, industrial mining enterprises and new energy power stations.

The series adopts high-efficiency DC boost circuit and high-precision micro-current sampling technology, realizing standard insulation diagnostic measurements: insulation resistance (IR), dielectric absorption ratio (DAR), polarization index (PI). The independent **GUARD shielding terminal effectively eliminates surface leakage interference caused by humid and contaminated environments and improves measurement stability.

Specifications

Parameter MRT-3127A MRT-3127B
Max DC Test Voltage 5000V 10000V
Fixed Voltage Gears 250V/500V/1kV/2.5kV/5kV 250V/500V/1kV/2.5kV/5kV/10kV
Max Measuring Range 2 TΩ 5 TΩ
Minimum Measurement Range 0.1 MΩ 0.1 MΩ
Basic Accuracy ±3% reading ±5 digits ±3% reading ±5 digits
Max Short-Circuit Current ≥5mA ≥5mA
Test Modes IR, DAR (Absorption Ratio), PI (Polarization Index)
Terminals HV, GROUND, GUARD shield terminal
Display 4.3" color capacitive touch screen, CN/EN bilingual
Data Storage Built-in memory, hundreds of records with timestamp
Communication USB 2.0 (U-disk export + PC software)
Safety Functions Zero start interlock, HV sound-light alarm, auto discharge, breakdown protection, over-temperature protection
Power Supply Built-in lithium battery; AC 100~240V charging adapter
Continuous Battery Life ≥7 hours ≥7 hours
Operating Temperature -10℃ ~ +50℃
Ambient Humidity ≤85% RH (non-condensing)
Enclosure Shockproof portable reinforced plastic case with handle

Applications

Core Test Objects

  • Distribution & power transformers
  • Medium voltage power cables, cable joints and terminals
  • Motors, generators and rotating electrical equipment
  • Switchgear, current transformers, voltage transformers
  • Insulating supports, winding insulation components

Typical Application Scenarios

  • Power grid operation & maintenance: routine preventive test, equipment insulation condition evaluation
  • New energy power stations: wind turbine, photovoltaic transformer insulation inspection
  • Industrial & mining enterprises: internal power equipment periodic maintenance
  • Third-party testing institutions: engineering acceptance and insulation diagnostic testing
  • Electrical manufacturers: factory quality inspection

Advantages

Cost-effective two-model gradient lineup

5kV /10kV matched for medium voltage equipment, economical choice for grassroots operation & maintenance teams

Standard IR+DAR+PI complete insulation diagnosis

Satisfy power industry preventive test specification requirements for transformer and cable insulation evaluation

GUARD anti-leakage shielding design

Solve measurement deviation caused by surface leakage under humid and polluted on-site conditions

Multi-layer safety protection system

Auto discharge, breakdown protection, high voltage alarm, zero interlock, guarantee operator safety

Battery-powered portable design

Suitable for outdoor off-grid preventive test without fixed AC power supply

FAQ

Q: How to select between MRT-3127A and MRT-3127B?

A: General selection principle:

  • MRT-3127A (5kV, 2TΩ): Mainly for 10kV distribution transformers, medium voltage cables, low and medium voltage motors
  • MRT-3127B (10kV, 5TΩ): For 35kV class transformers, longer HV cables and scenarios requiring higher test voltage and wider measurement range

Q: What is the function of GUARD shielding terminal?

A: The guard terminal diverts surface leakage current of insulation material. When testing under rainy, humid or dirty conditions, surface leakage will lead to low reading deviation. Connecting guard wire can bypass leakage current, so the instrument only measures internal volume insulation resistance and improves test accuracy.

Q: Difference between DAR and PI?

  • DAR (Absorption Ratio): R60s/R15s, reflects medium-short time insulation absorption characteristics, widely used for cables and motors
  • PI (Polarization Index): R10min/R1min, evaluates deep insulation aging and moisture ingress, primary index for large power transformers

Q: Must discharge after measurement?

A: The instrument has built-in automatic discharge circuit. But for long cables and large capacitive test objects, please wait sufficient discharge time and confirm voltage returns to zero before touching test terminals to avoid residual electric shock hazard.