Description

The GDFR-20 is a high-precision, portable resistor-capacitor (RC) divider designed for accurate AC/DC high voltage measurement in power systems, industrial testing, and research laboratories. It adopts advanced RC parallel voltage division principle and high-stability metal film resistors + low-loss polypropylene capacitors, delivering excellent linearity, low dielectric loss, and long-term stability.

Unlike traditional oil-filled dividers, the GDFR-20 uses dry polyurethane foam filling, eliminating oil leakage, environmental pollution, and maintenance requirements. It features a fully sealed epoxy glass fiber cylinder with equal potential shielding structure, providing superior anti-interference performance and insulation strength. With a standard BNC interface, it can be directly connected to oscilloscopes, digital multimeters, and high-voltage test equipment for real-time voltage measurement and waveform analysis. Ideal for calibrating DC high voltage generators, AC withstand test sets, and verifying the output accuracy of various high-voltage power supplies.

Specifications

Parameter

Specification

Rated Voltage

20kV AC (RMS) / 20kV DC (peak)

Measurement Accuracy

AC: ±0.5% of reading;DC: ±0.5% of reading

Linearity Error

≤±0.2%

Long-Term Stability

≤±0.2%/year

Temperature Coefficient

≤±50ppm/°C

Frequency Range

40Hz–10kHz

Frequency Response Error

≤±0.5% (40Hz–1kHz);≤±1.0% (1kHz–10kHz)

Dielectric Loss (tanδ)

≤0.001 at 50Hz

Voltage Division Ratio

1000:1 (standard);10000:1 (customizable)

Insulation Resistance

≥1000MΩ (at 25°C)

Withstand Voltage

1.1× rated voltage for 1 minute

Partial Discharge

≤10pC at rated voltage

Interface

Standard BNC

Measurement Cable Length

4m (shielded)

Filling Medium

Dry polyurethane foam

Insulation Cylinder Material

Epoxy glass fiber reinforced plastic

Dimensions (mm)

Φ220×610

Weight

~6.5kg

Operating Temperature

0°C ~ +45°C

Relative Humidity

≤85%RH (non-condensing)

Altitude

≤1500m (customizable for higher altitude)

Compliance

DL/T 846.1-2004, IEC 61010-1 CAT III 1000V, CE

Applications

Core Measurement Objects

  • DC high voltage generators: output voltage calibration
  • AC withstand test sets: output voltage verification
  • Power transformers: winding AC/DC voltage measurement
  • Zinc oxide arresters (MOA): reference voltage test
  • High-voltage capacitors: voltage division and measurement
  • Pulse power supplies: pulse voltage waveform analysis

Typical Usage Scenarios

  • Power system testing: substation equipment commissioning and preventive maintenance
  • Laboratory research: high-voltage physics experiments and calibration
  • Manufacturing quality control: high-voltage equipment production line testing
  • Field calibration: on-site verification of portable high-voltage testers
  • Education and training: university and vocational school high-voltage experiments

Advantages

Dual-Use & High Precision

20kV AC/DC measurement with ±0.5% accuracy → meets the strict requirements of power industry calibration

Wide Frequency Response

40Hz–10kHz bandwidth → suitable for power frequency, square wave, and pulse voltage measurement

Dry & Maintenance-Free

No oil, no leakage, no pollution → safe, environmentally friendly, and low maintenance cost

Portable & Compatible

6.5kg lightweight + BNC interface → easy to carry and connect to various measurement instruments

Long-Term Stability

High-stability components + equal potential shielding → reliable performance and long calibration cycle

FAQ

Q: Is GDFR-20 suitable for both AC and DC high voltage measurement?

A: Yes. It is designed for 20kV AC (RMS) and 20kV DC (peak) measurement with the same ±0.5% accuracy.

Q: What is the standard voltage division ratio? Can it be customized?

A: The standard ratio is 1000:1. Custom ratios such as 10000:1 are available upon request.

Q: Can it be connected to an oscilloscope for waveform analysis?

A: Yes. It has a standard BNC interface and comes with a 4m shielded cable, which can be directly connected to oscilloscopes, digital multimeters, and data loggers.

Q: Is it oil-filled or dry?

A: It uses dry polyurethane foam filling, which is oil-free, leak-proof, pollution-free, and maintenance-free.

Q: What is included in the standard package?

A: GDFR-20 RC divider main unit, 4m shielded BNC measurement cable, BNC to banana plug adapter, dedicated carrying case, user manual, and calibration certificate.

Get a Free Quote

Our representative will contact you soon.
Email
Mobile/WhatsApp
Name
Company Name
Message
0/1000

Get a Free Quote

Our representative will contact you soon.
Email
Mobile/WhatsApp
Name
Company Name
Message
0/1000