GDBD-B 110V60A Intelligent Battery Discharge Tester
GDBD-B 110V60A Digital Intelligent Constant Current Battery Discharge Tester with 20-125V Dedicated Voltage Range, Single Cell Voltage Monitoring, 7" Touch Screen, for 110V Substation Lead-Acid Battery Pack Capacity Verification
- Description
- Specifications
- Applications
- Advantages
- FAQ
- Recommended Products
Description
GDBD-B 110V60A is a professional 110V system dedicated intelligent constant current battery discharge tester designed for capacity verification, routine maintenance and activation of lead-acid battery packs in 110kV substations, power plants, industrial enterprises and UPS systems. It strictly complies with DL/T 724-2000, DL/T 1392-2014 and IEC 60896-2:2008 standards, adopting 20-125V precision voltage design that is optimized for 110V DC power systems, providing higher accuracy and stability than general-purpose wide-voltage testers.
The instrument uses high-precision nickel-chromium alloy resistors as discharge load, featuring low temperature coefficient, no red heat phenomenon and long service life. Its advanced closed-loop constant current control technology ensures stable discharge current with ±1% accuracy throughout the entire discharge process, even as battery voltage drops. The 7-inch high-definition color touch screen provides intuitive operation and real-time display of battery pack voltage, discharge current, elapsed time, discharged capacity and single cell voltage histogram.
Specifications
| Parameter | Specification |
|---|---|
| Compliance Standards | DL/T 724-2000, DL/T 1392-2014, IEC 60896-2:2008, IEEE 1188-2005 |
| Discharge Voltage Range | 20V ~ 125V DC (dedicated for 110V systems) |
| Discharge Current Range | 0A ~ 60A DC continuous adjustable |
| Current Control Accuracy | ±1% FS |
| Voltage Measurement Accuracy | ±0.5% FS + 0.1V |
| Current Measurement Accuracy | ±1% FS + 0.1A |
| Voltage Resolution | 0.1V |
| Current Resolution | 0.1A |
| Single Cell Voltage Range | 0V ~ 3V (for 2V cells) |
| Single Cell Voltage Accuracy | ±0.3% FS + 0.01V |
| Maximum Number of Single Cells | 108 cells |
| Capacity Measurement Range | 0Ah ~ 9999Ah |
| Discharge Load Type | High-precision nickel-chromium alloy resistor |
| Cooling Method | Intelligent forced air cooling |
| Display | 7-inch 1024×600 color TFT touch screen |
| Data Storage | 128MBit, stores 200 groups of test data + curves + single cell data |
| Communication Interfaces | USB 2.0 (U-disk export), RS485 (remote control) |
| Termination Conditions | Discharge voltage, discharge time, discharge capacity, single cell voltage, manual stop |
| Protection Functions | Over-voltage, under-voltage, over-current, over-temperature, reverse polarity, short circuit, fan fault, emergency stop |
| Power Supply | AC 220V±15%, 50Hz±2Hz |
| Power Consumption | ≤7.5kW (peak at 125V/60A) |
| Operating Temperature | -10℃ ~ +50℃ |
| Humidity | ≤85% RH (non-condensing) |
| Dimensions (L×W×H) | 550×450×250mm |
| Weight | ~18kg (including all components) |
| Enclosure | Rugged aluminum alloy, IP40 |
Applications
Core Test Objects
- Lead-acid battery packs: 2V series-connected valve-regulated lead-acid (VRLA) batteries for 110V DC systems
- Substation DC systems: 110V control power systems, protection power systems and communication power systems
- Backup power systems: 110V UPS systems, EPS systems, data center backup power
- Renewable energy systems: 110V solar photovoltaic power systems, wind power energy storage systems
Typical Usage Scenarios
- Power companies: 110kV~500kV substation battery pack routine maintenance, capacity verification and acceptance test
- Power plants: Generator auxiliary power system battery pack performance test and life assessment
- Industrial enterprises: 110V backup power system maintenance and safety assessment
- Battery manufacturers: Factory quality control, type test and batch inspection of 110V battery packs
- Third-party testing institutions: Battery system certification testing, safety assessment and on-site calibration services
Advantages
Compliance with Latest Industry Standards
Fully meets DL/T 724-2000, DL/T 1392-2014, IEC 60896-2:2008 → test results are globally recognized
110V System Dedicated Design
20-125V precision voltage range optimized for 110V systems → higher accuracy and stability than general-purpose wide-voltage testers
60A High-Current Output
Supports discharge testing of large-capacity 110V battery packs up to 600Ah → meets the requirements of all mainstream 110V substation battery systems
Industry-Leading Single Cell Monitoring
Real-time monitoring of up to 108 single cells with dynamic histogram display → quickly identifies weak cells and ensures battery system safety
High-Precision Constant Current Control
±1% current accuracy, stable discharge throughout the entire process → ensures accurate and reliable battery capacity measurement
Safe & Reliable Nickel-Chromium Load
No red heat, no open flame, long service life → eliminates fire hazards during discharge testing
Comprehensive Real-Time Monitoring
FAQ
Q: Why is single cell voltage monitoring important?
A: Single cell voltage monitoring is crucial for identifying weak or degraded cells in a battery pack. A single weak cell can significantly reduce the overall capacity and reliability of the entire battery system. During discharge testing, weak cells will show a much faster voltage drop than normal cells. GDBD-B-110V60A's real-time single cell monitoring and histogram display allow you to quickly identify these weak cells before they cause system failures.
Q: How does the constant current control work?
A: The instrument adopts advanced closed-loop constant current control technology. It continuously monitors the discharge current in real time and automatically adjusts the load resistance to maintain the set current value, even as the battery voltage drops during discharge. This ensures that the discharge rate remains constant throughout the test, providing accurate and reliable capacity measurement results.
Q: Is it safe to discharge batteries with this instrument?
A: Yes. The instrument is equipped with an 8-level comprehensive safety protection system that protects both the battery and the instrument from various abnormal conditions. The nickel-chromium alloy load has no red heat phenomenon and no open flame, eliminating fire hazards. The reverse polarity protection prevents damage caused by incorrect battery connection.