All Categories
gdcy 20b digital intelligent basic impulse voltage tester -0

Lightning Impulse Generator

Home >  Products >  Lightning Impulse Generator

GDCY-20B Digital Intelligent Basic Impulse Voltage Tester

GDCY-20B Digital Intelligent Basic Impulse Voltage Tester (±20kV Peak Impulse, 0-±22kV DC) with 1.2/50μs Standard Lightning Impulse, ±3% Voltage Accuracy, Manual/Auto/Computer Programmable Modes, LCD Display, Touch Buttons, Leakage Current/Voltage Attenuation Breakdown Judgment, for SPD, Low-Voltage Appliance, Electronic Component, EV Charger Impulse Withstand Voltage Test.

  • Description
  • Specifications
  • Applications
  • Advantages
  • FAQ
  • Recommended Products

Description

The GDCY-20B is a cost-effective, basic-type desktop impulse voltage test systemexclusively designed for impulse withstand voltage tests of low-voltage electrical equipment and surge protective devices (SPD). It fully complies with IEC 61000-4-5:2014 and GB/T 17626.5-2019 standards, adopting advanced high-voltage solid-state switching technology to generate stable and repeatable 1.2/50μs standard lightning impulse waveforms.
The system features an integrated desktop design with a built-in standard impulse capacitor, supporting both DC withstand voltage test and impulse withstand voltage test. Equipped with a 128×64 LCD display and intuitive touch buttons, it supports three operation modes: manual, automatic, and computer programmable. It has dual breakdown judgment functions (leakage current and voltage attenuation) to automatically determine test results. With comprehensive safety protection including over-voltage, over-current, and emergency stop, it ensures safe and reliable operation in production lines and laboratories. Ideal for 3C certification tests, factory quality control, and basic research experiments of SPDs, low-voltage switchgear, electronic components, electric vehicle chargers, and household appliances.

Specifications

Parameter Specification
Impulse Output Voltage ±1kV–±20kV peak (1V step, ±3% accuracy)
DC Output Voltage 0–±22kV DC (continuous adjustable)
Main Impulse Capacitance 10nF (standard)
Rated Energy 2J
Output Waveform 1.2/50μs standard lightning impulse full wave
Waveform Parameters T1=1.2μs±30%, T2=50μs±20%
Peak Oscillation <5%
Waveform Repeatability ≤±1%
Charging Voltage Accuracy ≤±3% (full range, calibratable)
Impulse Voltage Measurement Accuracy ≤±3%
Charging Voltage Instability <±0.5%
Trigger Delay <1μs
Repetition Rate 1 impulse every 1–99 seconds (adjustable, default 5s)
Polarity Positive, Negative, Positive-Negative Alternating
Operation Modes Manual mode, Automatic mode, Computer programmable mode
Breakdown Judgment Leakage current (30mA–1200mA adjustable), Voltage attenuation (0%–99% adjustable)
Display 128×64 LCD display
Communication Interface RS485 (standard), USB (optional)
Data Management Test result display and storage, USB export (optional)
Protection Functions Over-voltage, Over-current, Short-circuit, Emergency stop, Ground detection, Automatic discharge
Dimensions (mm) 450×380×240 (W×H×D)
Weight ~12kg
Power Supply Single-phase AC220V±10%, 50Hz
Power Consumption ≤300VA
Operating Temperature 0℃ ~ +40℃
Operating Humidity ≤80%RH (non-condensing)
Altitude ≤2000m
Compliance IEC 61000-4-5:2014, GB/T 17626.5-2019, GB/T 18802.1-2020, IEC 61643-11:2011, GB 7251.1-2013

Applications

Core Test Objects

  • Surge Protective Devices (SPD): Class II, III SPDs (voltage limiting type)
  • Low-voltage switchgear: circuit breakers, contactors, relays, distribution boxes
  • Electronic components: capacitors, resistors, diodes, transistors
  • Electric vehicle chargers: AC chargers, charging piles
  • Household appliances: refrigerators, air conditioners, washing machines
  • Photovoltaic inverters: small grid-tied inverters
  • Wires and cables: low-voltage power cables and wires
  • Electricity meters: single-phase and three-phase electricity meters

Typical Usage Scenarios

  • Factory quality control: 100% outgoing inspection of finished products
  • 3C certification tests: basic safety certification tests for low-voltage products
  • On-site testing: field inspection of installed SPDs and electrical equipment
  • Small research laboratories: basic insulation performance research
  • Technical schools and universities: teaching and demonstration experiments
  • Third-party inspection: basic compliance testing

Advantages

DC + Impulse Dual Output

Supports both DC withstand and impulse withstand tests → one system covers two common test requirements

Dual Breakdown Judgment

Leakage current and voltage attenuation dual judgment → accurate and reliable test result determination

Three Flexible Operation Modes

Manual, automatic, and computer programmable modes → meets different test requirements from simple to complex

Ultra-Compact & Lightweight

12kg ultra-lightweight desktop design → easy to move and transport between production lines

Comprehensive Safety Protection

Multiple protection layers + automatic discharge → maximum safety for operators and test equipment

High Cost-Effectiveness

Optimized for basic test requirements, providing excellent performance at a competitive price → ideal for small and medium-sized enterprises

FAQ

Q: What is the difference between GDCY-20B and GDCY-20P?

A:
  • GDCY-20B (Basic Type): 128×64 LCD display + touch buttons, ±3% accuracy, 12kg weight, cost-effective, suitable for basic factory quality control
  • GDCY-20P (Advanced Type): 7-inch color touch screen, ±1% accuracy, 25kg weight, PDF report generation, suitable for certification laboratories and high-end manufacturers
    Both generate 1.2/50μs standard lightning impulse wave and meet IEC 61000-4-5 requirements.

Q: What waveforms can GDCY-20B generate?

A: It generates 1.2/50μs standard lightning impulse full wave as standard, which is the most commonly used waveform for low-voltage equipment impulse tests according to IEC 61000-4-5. It also supports 0–±22kV DC withstand voltage test.

Q: What is the breakdown judgment function?

A: It has two breakdown judgment methods:
  1. Leakage current judgment: Alarms when the leakage current exceeds the set threshold (30mA–1200mA)
  2. Voltage attenuation judgment: Alarms when the impulse voltage peak drops below the set percentage (0%–99%)
    The system automatically determines pass/fail and stops the test when breakdown occurs.

Q: Does it support computer control?

A: Yes. It has an RS485 communication interface and comes with dedicated Windows-based control software (optional) for remote operation, parameter setting, and data analysis.