GDYD-1010C Manual Digital Cascade AC Hipot Tester

  • Description
  • Specifications
  • Applications
  • Advantages
  • FAQ
  • Recommended Products

Description

The GDYD-1010C is a professional field-oriented cascade power frequency withstand voltage test system designed for insulation strength test of 110kV and below high-voltage electrical equipment in remote substations, power plants, and construction sites. It fully complies with DL/T 848.2-2004 and GB/T 16927.1-2011, adopting an innovative 2-stage cascade structure consisting of two identical 5kVA/50kV oil-immersed test transformers, which can be easily transported separately and assembled on site in 10 minutes, solving the problem of heavy single-unit 100kV transformers being difficult to move.

Equipped with a portable digital control box and high-brightness 4-digit LED meters, it provides real-time display of high-voltage side voltage, current, and test time with clear readings even under strong sunlight. It features smooth manual voltage regulation, 1s-99H adjustable timing function, and comprehensive safety protection including zero-start, over-current, breakdown, and emergency stop, ensuring maximum safety for operators and test samples. The system supports both cascade operation (100kV/10kVA) and single-stage operation (50kV/10kVA), offering flexible configuration for different test requirements. Ideal for on-site commissioning, periodic maintenance, and acceptance tests of 110kV power transformers, GIS, XLPE power cables, insulators, and bushings.

Specifications

Parameter

Specification

Input Power

Single-phase AC220V±10%, 50Hz

Rated Capacity

10kVA (cascade) / 10kVA (single-stage)

Rated Output Voltage

0–100kV AC (cascade) / 0–50kV AC (single-stage)

Rated Output Current

100mA (cascade) / 200mA (single-stage)

Output Waveform Distortion

≤3%

Measurement Accuracy

Voltage ±1.5% F.S;Current ±2.5% F.S

Display

3 independent 4-digit digital LED meters

Timing Range

1s–99H adjustable;audible and visual alarm

Protection Functions

Zero-start, Over-current (10–110% adjustable), Breakdown, Emergency stop, Cascade interlock

Cooling Method

Oil-immersed self-cooling

Control Box Dimensions (mm)

450×350×250

Single Transformer Dimensions (mm)

Φ280×650 (including grading ring)

Weight

Control box: ~25kg;Single transformer: ~45kg;Total: ~115kg

Operating Temperature

-20℃ ~ +50℃;Humidity ≤85%RH (non-condensing)

Compliance

DL/T 848.2-2004, DL/T 474.4-2006, GB/T 16927.1-2011, IEC 60060-1, IEC 61010-1 CAT III 1000V

Applications

Core Test Objects

  • Power transformers: 10kV–110kV distribution and power transformers
  • GIS & switchgear: 110kV gas-insulated switchgear, vacuum breakers, busbars
  • Power cables: 10kV–110kV XLPE insulated power cables
  • Insulators & bushings: high-voltage insulators, transformer bushings
  • Electrical safety tools: insulating gloves, boots, rods, blankets (single-stage mode)
  • Capacitors & motors: medium-voltage insulation test

Typical Usage Scenarios

  • Remote substation commissioning: new equipment acceptance tests in hard-to-reach locations
  • Preventive maintenance: periodic insulation strength tests
  • Construction site testing: on-site test of newly installed equipment
  • Factory quality control: production line testing of medium-voltage equipment
  • Emergency fault diagnosis: insulation degradation or damage detection

Advantages

Dual-Mode Operation

Cascade (100kV/10kVA) + single-stage (50kV/10kVA) → one system covers all test requirements from 10kV to 110kV

4-Digit High-Brightness Display

Clear readings even under strong sunlight → eliminates reading errors in field environments

Comprehensive Safety Protection

Multiple protection layers + hard-wired emergency stop → maximum safety for operators and expensive test equipment

Oil-Immersed Self-Cooling

Excellent heat dissipation;30 minutes continuous full-load operation → suitable for long-duration field tests

Simple On-Site Assembly

Tool-free connection between transformers → assembled and ready for test in 10 minutes

FAQ

Q: Can it be used as a single 50kV test system?

A: Yes. It supports both cascade (100kV/10kVA) and single-stage (50kV/10kVA) operation, offering flexible configuration for different test requirements.

Q: How long does it take to assemble the cascade system on site?

A: With tool-free quick connectors, the system can be assembled and ready for test in 10 minutes by two people.

Q: What protection functions does it have?

A: Zero-start protection, adjustable over-current protection, breakdown protection, hard-wired emergency stop, and cascade connection interlock.

Get a Free Quote

Our representative will contact you soon.
Email
Mobile/WhatsApp
Name
Company Name
Message
0/1000

Get a Free Quote

Our representative will contact you soon.
Email
Mobile/WhatsApp
Name
Company Name
Message
0/1000