All Categories
54 digital intelligent variable frequency series resonant withstand voltage test system-0

AC Resonant Test System

Home >  Products >  AC Resonant Test System

GDTF-162/54 Digital Intelligent Variable Frequency Series Resonant Withstand Voltage Test System

  • Description
  • Specifications
  • Applications
  • Advantages
  • FAQ
  • Recommended Products

Description

The GDTF-162/54 is a professional, field-optimized variable frequency series resonant test system exclusively designed for 35kV long XLPE power cables and substation electrical equipment AC withstand voltage tests. It fully complies with DL/T 849.6-2016 and GB 50150-2016 standards, adopting the series resonance principle to generate high voltage and large current with only a small input power, solving the problem of traditional test transformers being too heavy and having insufficient capacity for large capacitive loads.

The system consists of a variable frequency control power supply, excitation transformer, 6 identical 27kV/1A dry-type epoxy-cast reactors, and a 0.5-class standard capacitor divider.. The reactors can be flexibly connected in series or parallel to adapt to different test voltage and current requirements. Equipped with a 7-inch color touch screen and advanced automatic frequency sweep algorithm, it can automatically find the resonance point within 30 seconds, complete the entire test process with one click, and store all test data for traceability. With single-phase 220V input (compatible with field generators) and lightweight single reactor design (≤27kg), it is ideal for on-site commissioning and preventive maintenance tests of 35kV XLPE power cables, GIS, power transformers, bushings, insulators, and switchgear.

Specifications

Parameter

Specification

Input Power

Single-phase AC220V±10%, 50Hz

Rated Output Capacity

162kVA

Rated Output Voltage

0–54kV AC (RMS)

Rated Output Current

3A (2 串 3 并) / 6A (6 并联)

Reactor Configuration

6×27kV/1A dry-type epoxy-cast reactors

Combination Modes

27kV/6A, 54kV/3A

Operating Frequency Range

30Hz–300Hz

Frequency Resolution

0.1Hz

Frequency Stability

≤0.01%

System Quality Factor (Q)

≥30 (typical 30–50)

Output Waveform Distortion

≤1%

Voltage Measurement Accuracy

≤±1.5% F.S

Current Measurement Accuracy

≤±1.5% F.S

Test Modes

Automatic test, Manual test, Timed test

Timing Range

0–9999s adjustable

Display

7-inch color touch screen

Data Storage

1000 groups (with time stamp)

Data Export

USB flash drive

Protection Functions

Zero-start, Over-voltage, Over-current, Flashover, Emergency stop, Ground detection, Over-temperature

Continuous Operation Time

60 minutes at full load

Operating Temperature

-10℃ ~ +40℃

Operating Humidity

≤85%RH (non-condensing)

Compliance

DL/T 849.6-2016, GB 50150-2016, GB/T 16927.1-2011, IEC 60060-1, IEC 61010-1 CAT III 1000V

Applications

Core Test Objects (35kV System)

  • XLPE power cables: 35kV/300mm² cables ≤1.2km, 10kV/300mm² cables ≤3km
  • GIS & gas-insulated switchgear: 35kV GIS, circuit breakers, disconnectors, busbars
  • Power transformers: 35kV power transformers and distribution transformers
  • Bushings & insulators: 35kV transformer bushings, post insulators, suspension insulators
  • Switchgear & cabinets: 10kV–35kV medium-voltage switchgear
  • Capacitors & reactors: high-voltage power capacitors and reactors

Typical Usage Scenarios

  • Substation commissioning: new equipment acceptance tests according to GB 50150-2016
  • Preventive maintenance: periodic insulation strength tests
  • Power plant testing: auxiliary transformer and switchgear tests
  • Third-party inspection: compliance testing and certification
  • Construction site testing: on-site test of newly installed equipment

Advantages

97% Energy Saving vs Traditional Test Transformers

Series resonance principle reduces input power to only 1/Q of output power → small input power, light weight, easy to transport

Single-Phase 220V Input

Compatible with field generators and ordinary power outlets → no need for three-phase power supply, convenient for remote sites

Ultra-Lightweight Single Reactor

27kg per reactor, single-person portable → easy to carry and assemble in remote substations without lifting equipment

Flexible Reactor Combination

6-stage 27kV reactors can be connected in series or parallel → one system covers all test requirements from 10kV to 35kV

FAQ

Q: What is the difference between GDTF-162/54 and GDTF-108kVA-108kV?

A:

  • GDTF-162/54: 54kV peak output, 162kVA capacity, single-phase 220V input, 6×27kV reactors, optimized for 35kV long cables and substation equipment
  • GDTF-108kVA-108kV: 108kV peak output, 108kVA capacity, three-phase 380V input, 4×27kV reactors, optimized for 110kV substation equipment

Both use the same series resonance principle and automatic frequency sweep technology.

Q: What is the maximum length of 35kV XLPE cable that can be tested?

A: With 3A rated current at 54kV, it can test up to 1.2km of 35kV/300mm² XLPE power cable or 3km of 10kV/300mm² XLPE power cable.

Q: Does it require three-phase power supply?

A: No. It adopts single-phase AC220V input, which is compatible with field generators and ordinary power outlets, making it ideal for remote sites without three-phase power.