All Categories
150kv intelligent pd free test complete set-0

Partial Discharge Test System

Home >  Products >  Partial Discharge Testers >  Partial Discharge Test System

GDYT-A-15kVA/150kV Intelligent PD-Free Test Complete Set

GDYT-A-15kVA/150kV Digital Intelligent Partial Discharge-Free Test Complete Set with Integrated PD-Free Transformer, Intelligent Control Console, Isolation Filter, Coupling Capacitor and Digital PD Detector, <1pC System Background Noise, One-Click Operation, for 110kV and Below Electrical Equipment Type Tests and Factory Inspection.

  • Description
  • Specifications
  • Applications
  • Advantages
  • FAQ
  • Recommended Products

Description

The GDYT-A-15kVA/150kV is a professional-grade, fully integrated intelligent PD-free test systemexclusively designed for power frequency withstand voltage and partial discharge tests of 110kV and below high-voltage electrical equipment. It fully complies with IEC 60270:2015, GB/T 7354-2018 and DL/T 848.3-2019 standards, adopting an all-system PD-free design that includes six core components: PD-free test transformer, intelligent control console, isolation filter transformer, coupling capacitor, protective resistor and digital partial discharge detector.
The system features an industry-leading <1pC system background noise, ensuring accurate detection of extremely weak partial discharge signals from the test object. Its innovative PLC+10-inch touch screen intelligent control system supports one-click completion of the entire test process including voltage boosting, withstand voltage timing, partial discharge detection and voltage reduction. The integrated GDJF-2007 digital partial discharge detector provides professional PD analysis functions including PRPD maps, spectrum analysis and automatic discharge type identification. Equipped with comprehensive safety protection functions such as overvoltage, overcurrent, flashover and short circuit protection, it ensures the safety of operators and equipment during high-voltage tests. The modular design allows for easy transportation and on-site assembly, making it suitable for both laboratory type tests and on-site acceptance tests. Ideal for factory type tests, outgoing quality control, third-party arbitration tests and power company on-site acceptance tests of power transformers, GIS, high-voltage cables, instrument transformers, surge arresters and other high-voltage electrical equipment.

Specifications

Parameter Specification
System Parameters
Compliance Standard IEC 60270:2015, GB/T 7354-2018, DL/T 848.3-2019
System Background Noise <1pC
Test Modes Power frequency withstand voltage test, Partial discharge test
Operation Modes Fully automatic mode, Manual mode
High Voltage Power Supply
Rated Capacity 15kVA
Input Voltage AC 380V±10%, 50Hz, three-phase four-wire
Output Voltage 0 ~ 150kV AC (continuous adjustable)
Output Current 0 ~ 100mA
Voltage Regulation Accuracy ±1%
Waveform Distortion <3%
Rated Operation Time 30 minutes continuous at rated load
PD Detection Parameters
PD Detector Model Integrated GDJF-2007
Sampling Rate 100MS/s per channel
Resolution 12-bit
Detection Sensitivity 0.1pC
Measurement Range 0.1pC ~ 10000nC
Dynamic Range >80dB
Frequency Bands 9 standard combinations (10kHz~1MHz)
Map Display PRPD, waveform, spectrum, pulse count, trend
Control Parameters
Control Architecture PLC + 10-inch industrial touch screen
Timing Range 0 ~ 9999s (adjustable)
Data Storage Unlimited internal storage
Report Generation Automatic Word/PDF report generation
Communication USB, LAN
Safety Protection
Overvoltage Protection Yes (adjustable threshold)
Overcurrent Protection Yes (adjustable threshold)
Flashover Protection Yes
Short Circuit Protection Yes
Zero Position Protection Yes
Door Interlock Protection Yes
Emergency Stop Button Yes
General Parameters
Power Consumption <20kW
Total Weight ~350kg (complete set)
Modular Design Yes (6 independent modules)
Quick Connection Yes (standardized connectors)
Wheeled Design Yes (all components)
Operating Temperature -10℃ ~ +50℃
Operating Humidity ≤90% RH (non-condensing)
Altitude ≤2000m

Applications

Core Test Objects

  • Power transformers: 10kV~110kV oil-immersed and dry-type power transformers
  • GIS equipment: 110kV and below GIS and HGIS gas insulated switchgears
  • High-voltage cables: 10kV~110kV XLPE power cables, cable terminals and joints
  • Instrument transformers: 10kV~110kV current transformers (CT) and voltage transformers (VT)
  • Surge arresters: 10kV~110kV zinc oxide surge arresters
  • Other equipment: Capacitors, reactors, bushings, high-voltage switches

Typical Usage Scenarios

  • Electrical equipment manufacturers: Factory type tests and outgoing quality control
  • Third-party testing institutions: Arbitration tests and compliance certification
  • Power companies: High-voltage equipment acceptance tests and fault diagnosis
  • Power engineering companies: Power grid construction and renovation project acceptance
  • Technical schools and universities: Teaching and demonstration experiments

Advantages

Compliance with International Arbitration Standards

Fully meets IEC 60270:2015 standard, test results are globally recognized and legally valid → can be used as arbitration basis for quality disputes

Industry-Leading <1pC System Background Noise

All components are PD-free optimized, ensuring the purest test voltage → accurately detects extremely weak partial discharge signals in the test object

One-Click Full Process Automation

Automatically completes the entire test process without manual intervention → greatly improves test efficiency, ideal for batch production lines

Integrated Professional PD Detection

No need for separate PD detector purchase and connection → reduces system complexity and total investment cost

Comprehensive Safety Protection System

Multiple protection functions and safety interlocks → ensures the safety of operators and equipment during high voltage testing

Modular Design & Easy Transportation

Quick assembly and disassembly, wheeled design → suitable for both laboratory fixed use and on-site mobile testing

Standardized Automatic Report Generation

Generates IEC-compliant test reports with one click → eliminates manual report writing, ensures data consistency and traceability

High Cost-Effectiveness

Provides complete PD and withstand voltage test capability at a price only 70% of imported systems → the most cost-effective solution for electrical equipment manufacturers

FAQ

Q: What is the system background noise of GDYT-A-15kVA/150kV?

A: The system adopts an all-system PD-free design. The partial discharge of each component is strictly controlled: test transformer <0.5pC, coupling capacitor <0.3pC, protective resistor <0.2pC. The total system background noise is <1pC at rated voltage, which meets the IEC 60270 arbitration level requirements.

Q: What components are included in the complete set?

A: The complete set includes six core components:
  1. GDYT-A-15kVA/150kV PD-free test transformer
  2. Intelligent control console (with built-in PLC and touch screen)
  3. 15kVA isolation filter transformer
  4. OWF-150kV/1000pF PD-free coupling capacitor
  5. BR-150kV/10kΩ PD-free protective resistor
  6. Integrated GDJF-2007 digital partial discharge detector

Q: Can it automatically complete the entire test process?

A: Yes. The system supports one-click fully automatic operation. Users only need to set the test voltage, withstand time and PD threshold, and the system will automatically complete voltage boosting, withstand voltage timing, PD detection, voltage reduction and report generation without manual intervention.

Get a Free Quote

Our representative will contact you soon.
Email
Mobile/WhatsApp
Name
Company Name
Message
0/1000

Get a Free Quote

Our representative will contact you soon.
Email
Mobile/WhatsApp
Name
Company Name
Message
0/1000