All Categories
gdfr r 60 60kv 001 grade dc standard resistance voltage divider-0

High Voltage Divider

Home >  Products >  HV Test Equipment >  High Voltage Divider

GDFR-R-60 60kV 0.01% Grade DC Standard Resistance Voltage Divider

  • Description
  • Specifications
  • Applications
  • Advantages
  • FAQ
  • Recommended Products

Description

The GDFR-R-60 is a national metrology grade DC standard resistance voltage divider designed for ultra-high precision DC high voltage measurement and traceable calibration in national/regional metrology institutes, high-voltage laboratories, and power equipment manufacturers. It fully complies with JJG 1007-2005 and DL/T 846.1-2016, adopting SF6 fully sealed gas insulation and balanced multi-layer equipotential shielding structure to eliminate surface leakage current and electromagnetic interference, ensuring long-term measurement accuracy and stability.

Equipped with imported ultra-high precision non-inductive metal film resistors and precision temperature compensation technology, it achieves ±0.01% measurement accuracy and ≤0.005% annual ratio stability, with an ultra-low temperature coefficient of 0.2ppm/℃. It features three standard voltage divider ratios (10³:1, 10⁴:1, 10⁵:1) and BNC low-voltage output interface, compatible with all mainstream high-precision digital multimeters (Agilent, Fluke, etc.). With a compact, portable design and 25kg total weight, it is suitable for both laboratory calibration and on-site field testing of DC high voltage equipment.

Specifications

Parameter

Specification

Rated DC Voltage

60kV (positive/negative polarity)

Input Resistance

100MΩ

Equipotential Shielding Resistance

200MΩ

Standard Voltage Divider Ratios

10³:1 (60V output), 10⁴:1 (6V output), 10⁵:1 (600mV output)

Measurement Accuracy

±0.01% of reading (20℃±2℃)

Annual Ratio Stability

≤0.005%

Temperature Coefficient

≤0.2ppm/℃

Linearity Error

≤±0.005%

Insulation Medium

SF6 gas (0.4MPa)

Output Interface

BNC 50Ω shielded connector

Operating Temperature

-10℃ ~ +40℃;Humidity ≤85%RH (non-condensing)

Calibration Temperature

20℃±2℃

Housing Material

Fully sealed aluminum alloy

Dimensions (mm)

400×400×620 (including base)

Weight

~25kg

Compliance

JJG 1007-2005, DL/T 846.1-2016, GB/T 16927.2-2013, IEC 61010-1 CAT III 1000V

Applications

Core Test Objects

  • DC high voltage generators: traceable calibration of output voltage accuracy
  • DC high voltage meters: calibration and verification
  • Zinc oxide arresters (MOA): DC reference voltage precision measurement
  • Power cables: DC withstand voltage test voltage measurement
  • Transformers & motors: DC insulation test voltage measurement
  • High-voltage power supplies: precision DC voltage measurement

Typical Usage Scenarios

  • National/regional metrology institutes: DC high voltage standard for traceability
  • High-voltage laboratories: precision DC high voltage measurement and calibration
  • Power equipment manufacturers: production line quality control and calibration
  • Electric power research institutes: high-voltage insulation research and testing
  • On-site substation testing: field calibration of DC high voltage test equipment

Advantages

0.01% Ultra-High Accuracy & 0.005% Annual Stability

National metrology grade precision;long-term measurement reliability → ensures test result validity and regulatory compliance

0.2ppm/℃ Ultra-Low Temperature Coefficient

Minimizes temperature drift;full accuracy guaranteed across -10℃~+40℃ → reliable measurements in any environment

SF6 Fully Sealed Insulation

Excellent insulation performance;anti-moisture, anti-corona, maintenance-free → long service life and stable performance

Three-Range Output & Universal Compatibility

Covers all common measurement ranges;compatible with all mainstream high-precision multimeters → plug-and-play, no additional equipment required

FAQ

Q: Is it a national metrology grade standard?

A: Yes. ±0.01% accuracy and ≤0.005% annual stability meet the requirements of JJG 1007-2005 for 0.01 grade DC high voltage dividers.

Q: What is the temperature coefficient?

A: ≤0.2ppm/℃, which is far below the industry standard of 50ppm/℃, ensuring minimal temperature drift.

Q: Can it be used with Fluke or Agilent multimeters?

A: Yes. It uses a standard BNC interface and three output ranges, compatible with all mainstream high-precision digital multimeters.

Q: Is it maintenance-free?

A: Yes. SF6 fully sealed structure;no air leakage, no need for regular maintenance.

Get a Free Quote

Our representative will contact you soon.
Email
Mobile/WhatsApp
Name
Company Name
Message
0/1000

Get a Free Quote

Our representative will contact you soon.
Email
Mobile/WhatsApp
Name
Company Name
Message
0/1000