Description

The GDYD-137D is a professional, portable digital manual control box designed for power frequency withstand voltage test systems, providing precise voltage regulation, real-time measurement, and comprehensive safety protection for test transformers. It fully complies with DL/T 848.2-2004 and DL/T 474.4-2006, adopting high-precision digital measurement technology and industrial-grade components to deliver stable performance and reliable operation in harsh field environments.

Equipped with 4 high-brightness 4-digit digital LED meters, it simultaneously displays high-voltage side voltage, high-voltage side current, low-voltage side current, and test time with clear readings even under strong sunlight. It features smooth manual voltage regulation, 1s-99H adjustable timing function, and comprehensive safety protection including zero-start, over-current, breakdown, and emergency stop, ensuring maximum safety for operators and test samples. Housed in a rugged aluminum alloy carrying case, it is compatible with all types of test transformers (oil-immersed, dry, SF6) and ideal for on-site commissioning, periodic maintenance, and factory quality control of power cables, transformers, switchgear, and insulators.

Specifications

Parameter

Specification

Input Power

Single-phase AC220V±10%, 50Hz

Rated Capacity

7kVA

Output Voltage

0-250V AC (linear adjustable, zero-start)

Rated Output Current

35A

Compatible Transformer Capacity

5kVA-20kVA

Voltage Ratio Setting

100:1 to 1000:1 (user-settable)

Display

4 independent 4-digit digital LED meters

Measured Parameters

HV voltage (0-140kV), HV current (0-50mA), LV current (0-35A), Time (1s-99H)

Measurement Accuracy

Voltage ±1.5% F.S;Current ±2.5% F.S

Timing Range

1s-99H adjustable;audible and visual alarm

Protection Functions

Zero-start, Over-current (10-110% adjustable), Breakdown, Emergency stop

Housing Material

Rugged aluminum alloy carrying case

Dimensions (mm)

490×370×510

Weight

~39kg

Operating Temperature

-20℃ ~ +50℃;Humidity ≤85%RH (non-condensing)

Compliance

DL/T 848.2-2004, DL/T 474.4-2006, GB/T 16927.1-2011, IEC 60060-1, IEC 61010-1 CAT III 600V

Applications

Core Application Scenarios

  • Power frequency withstand voltage test: control box for test transformer systems
  • On-site substation testing: commissioning and maintenance of 10kV-110kV electrical equipment
  • Factory quality control: production line testing of transformers, switchgear, and cables
  • Electrical safety tool testing: periodic testing of insulating gloves, boots, and rods
  • Research and development: laboratory insulation testing of new electrical products

Compatible Test Objects (with matching test transformer)

  • Power cables: 10kV-110kV XLPE/PVC insulated cables
  • Power transformers: 10kV-110kV distribution and power transformers
  • Switchgear & GIS: 10kV-110kV vacuum breakers, load switches, busbars
  • Insulators & bushings: high-voltage insulators, transformer bushings
  • Electrical safety tools: insulating gloves, boots, rods, blankets

Advantages

4-Channel Simultaneous Digital Display

Clear, high-brightness LED meters;real-time monitoring of all test parameters → eliminates reading errors, improves test efficiency

Comprehensive Safety Protection

Multiple protection layers + hard-wired emergency stop → maximum safety for operators and expensive test equipment

Wide Compatibility

Compatible with all types of test transformers (oil-immersed, dry, SF6) → flexible for different test requirements, reduces equipment investment

Portable Aluminum Alloy Case

Rugged, lightweight design;easy to transport and use in remote field locations → ideal for on-site substation testing

Simple Manual Operation

Intuitive knob and button control;no professional training required → easy to use for field technicians

Industrial-Grade Reliability

High-quality components and robust construction → long service life, stable performance in harsh environments

FAQ

Q: Is GDYD-137D a complete test system or just a control box?

A: It is an independent control box unit that needs to be used with a test transformer. It is compatible with all types of test transformers (oil-immersed, dry, SF6) with a capacity of 5kVA-20kVA.

Q: What parameters does it display?

A: It simultaneously displays high-voltage side voltage, high-voltage side current, low-voltage side current, and test time on 4 independent digital LED meters.

Q: Can it be used with different voltage ratio transformers?

A: Yes. The voltage ratio is user-settable from 100:1 to 1000:1, making it compatible with transformers of different voltage levels.

Get a Free Quote

Our representative will contact you soon.
Email
Mobile/WhatsApp
Name
Company Name
Message
0/1000

Get a Free Quote

Our representative will contact you soon.
Email
Mobile/WhatsApp
Name
Company Name
Message
0/1000