All Categories
gdzj 35s coil turn to turn impulse withstand voltage tester-0

Withstand Voltage Tester

Home >  Products >  HV Test Equipment >  Withstand Voltage Tester

GDZJ-35S Coil Turn-to-Turn Impulse Withstand Voltage Tester

  • Description
  • Specifications
  • Applications
  • Advantages
  • FAQ
  • Recommended Products

Description

The GDZJ-35S is a cost-effective, high-precision interturn insulation test instrument designed for turn-to-turn insulation strength verification of coils and windings in 35kV and below electrical equipment. It fully complies with GB/T 22714-2008 and IEC 60034-15:2005, adopting the pulse waveform comparison method to apply equivalent overvoltage impulses to windings, enabling fast and accurate detection of interturn short circuits, partial discharges, wiring errors, coil imbalance, and other insulation defects.

Equipped with dual independent high-voltage circuits and a 7-inch color touch screen, it supports simultaneous testing of two windings and real-time overlay display of impulse waveforms for direct visual comparison. The system automatically analyzes waveform similarity, provides clear pass/fail judgment, and stores all test data for traceability. With comprehensive safety protection including over-voltage, over-current, short-circuit, emergency stop, and door interlock, it ensures safe operation in both production lines and maintenance workshops. Ideal for quality control, commissioning, and overhaul testing of AC/DC motors, distribution transformers, reactors, inductors, current transformers, and other coil-based electrical equipment.

Specifications

Parameter

Specification

Input Power

Single-phase AC220V±10%, 50Hz

Impulse Voltage Range

0–35kV peak (continuous adjustable)

Voltage Accuracy

±5% F.S

Wavefront Time

0.1–0.5μs (standard-compliant)

Pulse Energy

30J

Pulse Repetition Frequency

6.25–50 times/second (adjustable)

Test Circuits

2 independent high-voltage output circuits

Display

7-inch color touch screen

Waveform Comparison

Real-time overlay display + automatic similarity calculation

Test Modes

Single test, Continuous test, Timed test

Data Storage

1000 groups (with time stamp)

Data Export

USB flash drive

Protection Functions

Over-voltage, Over-current, Short-circuit, Emergency stop, Door interlock, Automatic discharge

Dimensions (mm)

700×600×1600 (W×H×D)

Weight

~140kg

Operating Temperature

0℃ ~ +40℃

Operating Humidity

≤80%RH (non-condensing)

Compliance

GB/T 22714-2008, JB/T 10098-2000, JB/T 9615.1-2000, IEC 60034-15:2005, IEC 61010-1 CAT III 1000V

Applications

Core Test Objects

  • Electric motors: 35kV and below AC induction motors, DC motors, servo motors (stator and rotor windings)
  • Transformers: distribution transformers, power transformers, instrument transformers (CT/PT)
  • Reactors & inductors: power reactors, filter inductors, choke coils
  • Electrical appliances: contactors, relays, solenoid valves, ignition coils
  • Generators: small and medium-sized synchronous generators, alternators

Typical Usage Scenarios

  • Production line quality control: 100% interturn insulation test of finished motors and transformers
  • Motor repair workshops: post-overhaul insulation verification
  • Substation maintenance: 35kV transformer and reactor winding inspection
  • R&D laboratories: new product development and performance testing
  • Third-party inspection: compliance testing according to national and international standards

Advantages

Standard-Compliant Impulse Waveform

0.1–0.5μs wavefront time meets all major national and international standards → ensures test result validity and comparability

Dual Circuit Synchronous Comparison

Eliminates need for reference coils;direct comparison of two windings → faster test speed and higher accuracy

Automatic Waveform Analysis & Judgment

Intelligent algorithm calculates waveform similarity;reduces human error and improves test efficiency → ideal for high-volume production lines

Comprehensive Safety Protection

Multiple protection layers + door interlock + automatic discharge → maximum safety for operators and test equipment

User-Friendly Touch Screen Interface

Intuitive graphical operation;one-click parameter recall → easy to use for non-professional technicians

FAQ

Q: What is the difference between GDZJ-35S and GDZJ-45S?

A: GDZJ-35S has a maximum output voltage of 35kV, suitable for 35kV and below electrical equipment;GDZJ-45S has a maximum output voltage of 45kV, suitable for 45kV and below equipment. Both have dual high-voltage circuits and automatic waveform comparison functions.

Q: What products can GDZJ-35S test?

A: It can test all types of coil-based electrical equipment including 35kV and below AC/DC motors, distribution transformers, reactors, inductors, current transformers, relays, and ignition coils.

Q: Does the wavefront time meet international standards?

A: Yes. The wavefront time of 0.1–0.5μs fully complies with the requirements of GB/T 22714-2008 and IEC 60034-15:2005.

Q: Does it require a reference coil for testing?

A: No. The dual high-voltage circuit design allows direct comparison of two identical windings, eliminating the need for pre-prepared reference coils.

Get a Free Quote

Our representative will contact you soon.
Email
Mobile/WhatsApp
Name
Company Name
Message
0/1000

Get a Free Quote

Our representative will contact you soon.
Email
Mobile/WhatsApp
Name
Company Name
Message
0/1000