All Categories
gdkc 15d circuit breaker timing tester for sf6 vacuum gis breakers-0

Circuit Breaker Analyzer

Home >  Products >  Switchgear Test Equipment >  Circuit Breaker Analyzer

GDKC-15D Circuit Breaker Timing Tester for SF6 Vacuum GIS Breakers

HV HIPOT GDKC-15D high voltage circuit breaker analyzer tests 12-channel dynamic characteristics + 100A contact resistance in one unit. Ideal for SF6, vacuum breakers & GIS substation on-site maintenance.

  • Description
  • Specifications
  • Applications
  • Advantages
  • FAQ
  • Recommended Products

Description

The GDKC-15D is a professional-grade, flagship portable high voltage circuit breaker comprehensive analyzerexclusively designed for mechanical characteristic testing of vacuum, SF6, oil-minimum circuit breakers and disconnecting switches in power systems, electrical manufacturing and industrial enterprises. It fully complies with GB/T 1984-2014, DL/T 846.3-2017 and IEC 62271-100:2020 standards, adopting advanced 12-channel independent simultaneous acquisition technology that enables simultaneous testing of 6 main contacts and 6 auxiliary contacts, covering all mechanical characteristic parameters of various high voltage switches.
The instrument features an innovative all-in-one integrated design that integrates a DC10~250V/20A adjustable operating power supply and a 100A three-phase simultaneous loop resistance test module, replacing multiple traditional test instruments with one device. Its 0.01ms ultra-high time resolution and ±0.5% full-range measurement accuracy ensure accurate capture of all dynamic processes during switch operation. It supports comprehensive parameter testing including opening/closing time, synchronization, bounce, velocity, travel, coil current, energy storage time, closing resistance, graphite contact and double-end grounding measurement.

Specifications

Parameter Specification
System Parameters
Compliance Standard GB/T 1984-2014, DL/T 846.3-2017, IEC 62271-100:2020, GB/T 11022-2011
Acquisition Channels 12 independent channels (6 main contacts + 6 auxiliary contacts)
Operation Mode One-click fully automatic test / Manual test
Display 7-inch 800×480 color capacitive touch screen
Language Support Chinese / English bilingual
Data Storage 1000 groups test data + waveforms
Communication Interfaces USB 2.0, RS232
Upper Computer Software Yes (remote control, data analysis, report generation)
Time Measurement
Range 0.01ms ~ 20000.0ms
Resolution 0.01ms
Accuracy ±0.5% of reading
Synchronization Accuracy ±0.1ms
Velocity Measurement
Range 0 ~ 20.00m/s
Resolution 0.01m/s
Accuracy ±0.5% of reading
Travel Measurement
Vacuum Breaker 0 ~ 50.0mm, 0.1mm resolution
SF6 Breaker 0 ~ 300.0mm, 1mm resolution
Oil Breaker 0 ~ 600.0mm, 1mm resolution
Accuracy ±0.5% of reading
Loop Resistance Test
Test Current DC 50A / 100A (three-phase simultaneous)
Range 1μΩ ~ 10mΩ
Resolution 0.01μΩ
Accuracy ±0.5% of reading
Special Test Functions
Closing Resistance 0 ~ 10kΩ, 1Ω resolution, ±0.5% accuracy
Graphite Contact Yes
Double-End Grounding Yes
Built-in DC Power Supply
Output Range DC10 ~ 250V continuously adjustable
Maximum Output Current 20A continuous, 30A short-term
Output Time 0.01 ~ 20s adjustable
Power Supply
Input Power AC 220V±15%, 50Hz±1Hz
Power Consumption ≤50W (average), ≤500W (peak)
Physical Parameters
Dimensions 360×260×170mm (L×W×H)
Weight ~12kg (including all components)
Housing Rugged aluminum alloy chassis
Protection Grade IP54
Operating Temperature -10℃ ~ +50℃
Storage Temperature -20℃ ~ +60℃
Humidity ≤85% RH (non-condensing)
Altitude ≤2000m (customizable for higher altitudes)

Applications

Core Test Objects

  • Circuit Breakers: Vacuum circuit breakers (10kV~40.5kV), SF6 circuit breakers (110kV~1000kV), oil-minimum circuit breakers
  • Switchgear: Disconnecting switches, grounding switches, load switches, reclosers, sectionalisers
  • Contactors: High-voltage vacuum contactors, low-voltage AC contactors

Typical Usage Scenarios

  • Power companies: Substation preventive maintenance, circuit breaker regular inspection, fault diagnosis and analysis
  • Switchgear manufacturers: Factory quality control, batch production inspection, type test verification
  • Power plants: Generator circuit breaker test, auxiliary equipment switch inspection
  • Industrial enterprises: Internal electrical equipment maintenance, switchgear routine testing
  • Third-party testing institutions: Electrical equipment certification testing, on-site calibration services

Advantages

Compliance with Latest International Standards

Fully meets GB/T 1984-2014 Chinese national standard, DL/T 846.3-2017 industry standard and IEC 62271-100 international standard → test results are recognized by certification bodies worldwide

Industry-Leading All-In-One Integrated Design

Integrates 12-channel mechanical characteristic test, 100A loop resistance test and adjustable DC operating power supply into one device → one instrument replaces 3 traditional test instruments, reducing test time by 70%

12-Channel Simultaneous Acquisition Technology

6 main + 6 auxiliary contacts simultaneous sampling, 0.01ms time resolution, ±0.1ms synchronization accuracy → accurately captures all dynamic processes during switch operation, including subtle bounce and synchronization differences

Comprehensive Special Test Functions

Supports closing resistance, graphite contact and double-end grounding measurement → meets all test requirements of various high voltage switches, including special types

Built-in Rich Standard Parameter Library

Pre-stored 200+ mainstream switch model standard parameters, automatic comparison and qualified judgment → eliminates manual lookup errors and improves test efficiency

Intelligent Data Processing & Report Generation

Real-time waveform display, post-test re-calculation, one-click standardized report generation → simplifies data analysis and report writing, reduces operator workload

FAQ

Q: What types of high voltage switches can GDKC-15D test?

A: GDKC-15D can test almost all types of high voltage switches:
  • Vacuum circuit breakers: 10kV ~ 40.5kV indoor and outdoor vacuum circuit breakers
  • SF6 circuit breakers: 110kV ~ 1000kV SF6 circuit breakers and GIS combined electrical appliances
  • Oil-minimum circuit breakers: Traditional oil-minimum circuit breakers
  • Other switches: Disconnecting switches, grounding switches, load switches, reclosers and sectionalisers
It supports various test modes including single opening, single closing, open-close, close-open and open-close-open reclose sequences.

Q: What is the advantage of integrated loop resistance test compared to separate testers?

A: Traditional circuit breaker testing requires two separate instruments: a mechanical characteristic tester and a loop resistance tester. GDKC-15D integrates both functions into one device, providing the following advantages:
  • Reduced test time: No need to change wiring between different tests, completing all tests with one wiring
  • Lower cost: One instrument replaces two, reducing equipment purchase cost
  • Improved portability: Less equipment to carry, more convenient for on-site testing
  • Unified data management: All test data is stored in one device, facilitating unified management and report generation

Q: How does the double-end grounding test function work?

A: Double-end grounding test is a special test mode required for high voltage circuit breakers in substations where both sides of the breaker are grounded for safety. GDKC-15D adopts advanced isolated acquisition technology that can accurately measure the opening/closing time and synchronization of circuit breakers under double-end grounding conditions, eliminating the influence of ground potential difference. This function is essential for safe on-site testing in substations.

Q: Can it test graphite contact circuit breakers?

A: Yes. GDKC-15D has a dedicated graphite contact test mode. Graphite contacts have different electrical characteristics from metal contacts, and traditional test methods often produce inaccurate results. The dedicated graphite contact test mode of GDKC-15D uses special signal processing algorithms to accurately measure the opening/closing time and bounce characteristics of graphite contact circuit breakers.

Q: How to calibrate the instrument?

A: GDKC-15D can be calibrated using standard time generators, standard resistors and standard force gauges with accuracy not lower than 0.2 class. The calibration procedure is simple and fast:
  1. Enter the calibration mode in the instrument menu
  2. Follow the prompts to connect the standard equipment
  3. Complete the calibration of each parameter (time, resistance, velocity, travel)
  4. The instrument will automatically save the calibration coefficients
The instrument should be calibrated once every 12 months according to national metrology requirements.

Get a Free Quote

Our representative will contact you soon.
Email
Mobile/WhatsApp
Name
Company Name
Message
0/1000

Get a Free Quote

Our representative will contact you soon.
Email
Mobile/WhatsApp
Name
Company Name
Message
0/1000